CBNFC - ITEK MEGA PLATE STABILIZER, 38753
- MSDS: CBNFC
- Manufacturer: A B DICK CO GRAPHIC SYSTEMS DIV
- Product Name: ITEK MEGA PLATE STABILIZER, 38753
- National Stock Number: 6850-00N071124
Product Identification
Product ID:ITEK MEGA PLATE STABILIZER, 38753
MSDS Date:01/10/1994
FSC:6850
NIIN:00N071124
MSDS Number: CBNFC
Responsible Party
ROCHESTER, NY 14623
US
Emergency Phone: 312-763-1900
Info Phone: 800-752-5139
Preparer: KENNETH W PINTER
Cage: 1BT21
Contractor
Telephone: 716-475-9050
Cage: 1BT21
Ingredients
WATER
CAS: 7732-18-5
RTECS: ZC0110000
Fraction By Weight: 80-90%
OSHA PEL N/K
ACGIH TLV: N/K
POTASSIUM PHOSPHATE, MONOBASIC
CAS: 7778-77-0
Fraction By Weight: 5-10%
OSHA PEL N/K
ACGIH TLV: N/K
(ORAL,RAT) 4 G/KG
CAS: 107-21-1
RTECS: KW2975000
Fraction By Weight: 1-5%
OSHA PEL N/K
ACGIH TLV: C 50 PPM, VAPOR
EPA Report Quantity: 1 LB
DOT Report Quantity: 1 LB
0.25 LBS/GAL
RTECS: 9999999VO
OSHA PEL N/K
ACGIH TLV: N/K
Hazards
LD50 LC50 Mixture:SEE INGREDIENT 3
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:INGESTION:MAY CAUSE ABDOMINAL
DISCOMFORT OR PAIN, DIZZINESS, LUMBAR PAIN, OLIGURIA AND CENTRAL
NERVOUS SYSTEM DEPRESSION. MAY CAUSE KIDNEY DAMAGE. ETHYLENE GLYCOL
MAY BE FATAL. EYE:DISCOMFORT WI TH POSSIBLE TRANSIENT
CONJUNCTIVITIS. SERIOUS CORNEAL INJURY NOT ANTICIPATED.
INHALATION:MAY (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ:CAUSE IRRITATION TO NOSE, THROAT. HIGH
VAPOR CONCENTRATIONS MAY CAUSE NAUSEA, VOMITING HEADACHE AND
DIZZINESS. EFTS OF OVEREXP:EYE IRRITATION, NAUSEA, HEADACHE,
DIZZINESS, MAY CNS DEPRESSION. KIDNEY DAMAGE.
Medical Cond Aggravated by Exposure:NONE.
First Aid
First Aid:INGEST:IF CONSCIOUS, GIVE TWO GLASSES OF WATER. DO NOT INDUCE
VOMITING. SEEK MEDICAL ATTENTION. EYE:FLUSH WITH WATER THORO FOR AT
LEAST 15 MINUTES, SEEK MEDICAL ATTENTION. SKIN:REMOVE CONTAMD
CLOTHING & FLUSH EXPOSED AREA THOROUGHLY W/WATER. INHAL:REMOVE TO
FRESH AIR. IF DISCOMFORT PERSISTS, CALL A PHYSICIAN.
Fire Fighting
Flash Point:NONE
Extinguishing Media:NONE. MEDIA SUITABLE FOR SURROUNDING FIRE .
Fire Fighting Procedures:NONE. USE NIOSH/MSHA APPROVED SCBA & FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE.
Accidental Release
Spill Release Procedures:DIKE THE SPILL AND SOAK UP WITH ABSORBANT
MATERIAL. PREVENT LIQUID FROM ENTERING SEWERS.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:STORE AT ROOM TEMPERATURE. LAB COAT.
Other Precautions:CONTACT LENS WEARERS SHOULD WEAR REGULAR GLASSES.
Exposure Controls
Respiratory Protection:NONE REQUIRED. NIOSH/MSHA APPROVED RESPIRATOR
APPROPRIATE FOR EXPOSURE OF CONCERN .
Ventilation:MECHANICAL (GENERAL): ACCEPTABLE.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:LAB COAT. ANSI APPRVD EMERGENCY EYE WASH &
DELUGE SHOWER .
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.
Chemical Properties
Boiling Pt:B.P. Text:>212F,>100C
Spec Gravity:1.065
pH:5.55
Evaporation Rate & Reference:NOT KNOWN
Solubility in Water:COMPLETE
Appearance and Odor:COLORLESS LIQUID, ODORLESS.
Stability
Stability Indicator/Materials to Avoid:YES
NONE.
Stability Condition to Avoid:NONE.
Hazardous Decomposition Products:NONE.
Disposal
Waste Disposal Methods:IN ACCORDANCE WITH LOCAL, STATE, AND FEDERAL
REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.